1 DIVERTER OVERVIEW
1.1 APPLICATION
1.1.1 USE: Cyberco 30
degree diverters are used in low pressure pneumatic conveyor systems
and can be used with solid fluidized material such as kaolin, calcium
carbonate, pvc resin and other powdered products. They are designed
to hold a buildup of material within the valve during the conveying
operation. This buildup serves to help seal the gate against leakage
but it should clean itself out during the cleaning cycle.
1.1.2
CONFIGURATION: These valves feature a floating flap gate. The 4",
5" and 6" can be obtained as manually operated or air
actuated. The 8" is available only as air actuated. The
diverters are sold with either a straight or 15 degree adapter on the
inlet end of the valve. The straight adapter is used to configure a
"Y" type diverter and the 15 degree adapter that can be
rotated 180 degrees is used to configure a left or right hand line
diverter. Standard pillow block bearings and bulk packing seals are
used for easy maintenance.
1.1.3 CONSTRAINTS: Do not use these
valves in low pressure conveyors to convey stringy or shredded
material as this material will ball up within the gate area and
prevent the valves from switching. The diverters are not a clean
valve in the strict sense of the word since there are internal
crevices therefor this should be considered if contamination is a
problem.
1.2 INSTALLATION:
1.2.1 ORIENTATION: The diverters are
best-mounted horizontal but may be mounted vertical or on the side.
Side mounted valves may have a counter weight mounted to the shaft
control arm to offset the weight of the gate. This is not important
on the 4" and 5" but recommended with the 6" and
8".
1.2.2 LINE COUPLING: Various manufactures make couplings
to adapt our diverters into the conveyor line. Dresser series 38
couplings are suitable for schedule 40 piping and series 62 reducing
coupling will adapt our valves to the tubing sizes. Another way to
adapt to tubing is to weld short schedule 40 pipe stubs onto the
tubing and then use standard pipe couplings.
1.2.3 AIR &
ELECTRICAL: The air actuated diverters should be connected to a
regulated, lubricated, 80-100 psi air supply. The controls consist of
an air cylinder, 4way double solenoid control valve and two limit
switches. A typical schematic is provided but the customer performs
the wiring installation.

MANUAL DIVERTER VALVES
SIZE: 4" , 5" ,
6"
78DIV5C1-B1A1-(size) "Y" type DIVERTER
VALVE
78DIV5C1-B2A1-(size) R-HAND LINE DIVERTER
VALVE
78DIV5C1-B2A2-(size) L-HAND LINE DIVERTER VALVE
|
DIMENSIONS CHART |
||||
|
"E" |
7.21 |
8.23 |
9.28 |
10.28 |
|
"D" |
10.28 |
11.13 |
12.57 |
13.59 |
|
"C" |
7.09 |
7.88 |
8.67 |
10.25 |
|
"B" |
22.85 |
24.90 |
26.95 |
31.05 |
|
"A" |
4.50 |
5.58 |
6.63 |
8.63 |
|
SIZE |
( 4 ) |
( 5 ) |
( 6 ) |
( 8 ) |

AIR OPERATED DIVERTER VALVES
SIZE: 4" , 5"
, 6" , 8"
78DIV5C3-B1A1-(size) "Y" type DIVERTER
VALVE
78DIV5C3-B2A1-(size) R-HAND LINE DIVERTER
VALVE
78DIV5C3-B2A2-(size) L-HAND LINE DIVERTER VALVE